✨ New Arrivals Just Dropped!Explore
HomeStore

MHC Class II (I-A/I-E) Monoclonal Antibody (M5/114.15.2), eFluor 506, eBioscience

Product image 1

MHC Class II (I-A/I-E) Monoclonal Antibody (M5/114.15.2), eFluor 506, eBioscience

MHC Class II (I-A/I-E) Monoclonal Antibody (M5/114.15.2), eFluor 506, eBioscience

PRODUCT DETAILS

Host: Rat

Isotype: IgG2b, kappa

Clonality: Monoclonal

Clone: M5/114.15.2

Format: eFluor 506

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 0.125 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The M5/114.15.2 monoclonal antibody reacts with the mouse major histocompatibility complex class II, both I-A and I-E subregion-encoded glycoproteins (I-A b, I-A d, I-A q, I-E d, I-E k, not I-A f, I-A k, or I-A s). It detects a polymorphic determinant present on B cells, monocytes, macrophages, dendritic cells, and activated T lymphocytes from mice carrying the H-2 b, H-2 d, H-2 q, H-2 p, H-2 r and H-2 u but not from mice carrying the H-2 s or H-2 f haplotypes. The M5/114 mAb is reported to inhibit I-A-restricted T cell responses of the H-2 b, H-2 d, H-2 q, H-2 u but not H-2 f, H-2 k, or H-2 s haplotypes.

Applications Reported: This M5/ 114.15.2 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This M5/ 114.15.2 antibody has been tested by flow cytometric analysis of mouse splenocytes. This may be used at less than or equal to 0.125 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

eFluor 506 can be excited with the violet laser line (405 nm) and emits at 506 nm. We recommend using a 510/20 band pass filter, or equivalent. Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 405 nm; Emission: 506 nm; Laser: Violet Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$353.00
MHC Class II (I-A/I-E) Monoclonal Antibody (M5/114.15.2), eFluor 506, eBioscience
$353.00

Product Information

Shipping & Returns

Description

PRODUCT DETAILS

Host: Rat

Isotype: IgG2b, kappa

Clonality: Monoclonal

Clone: M5/114.15.2

Format: eFluor 506

Reactivity: Ms

Application: Flow Cytometry

Tested Dilution: 0.125 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The M5/114.15.2 monoclonal antibody reacts with the mouse major histocompatibility complex class II, both I-A and I-E subregion-encoded glycoproteins (I-A b, I-A d, I-A q, I-E d, I-E k, not I-A f, I-A k, or I-A s). It detects a polymorphic determinant present on B cells, monocytes, macrophages, dendritic cells, and activated T lymphocytes from mice carrying the H-2 b, H-2 d, H-2 q, H-2 p, H-2 r and H-2 u but not from mice carrying the H-2 s or H-2 f haplotypes. The M5/114 mAb is reported to inhibit I-A-restricted T cell responses of the H-2 b, H-2 d, H-2 q, H-2 u but not H-2 f, H-2 k, or H-2 s haplotypes.

Applications Reported: This M5/ 114.15.2 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This M5/ 114.15.2 antibody has been tested by flow cytometric analysis of mouse splenocytes. This may be used at less than or equal to 0.125 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

eFluor 506 can be excited with the violet laser line (405 nm) and emits at 506 nm. We recommend using a 510/20 band pass filter, or equivalent. Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 405 nm; Emission: 506 nm; Laser: Violet Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
MHC Class II (I-A/I-E) Monoclonal Antibody (M5/114.15.2), eFluor 506, eBioscience | Cytek Biosciences