PRODUCT DETAILS

Host: Mouse

Isotype: IgG1, kappa

Clonality: Monoclonal

Clone: V3GYWCH

Format: eFluor 450

Reactivity: Hu, Ms

Application: Flow Cytometry

Tested Dilution: 1.0 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The V3GYWCH monoclonal antibody reacts with human and mouse interferon regulatory factor 8 (IRF8; ICSBP). IRF8 is a 50 kDa transcription factor that plays a critical role in the development of dendritic cells (DC). Specifically, IRF8 is essential in the development and differentiation of plasmacytoid DC (pDC) and CD8a+ DC. IRF8-/- mice are deficient in both pDC and CD8a+ DC populations. CD8a- DC are present in normal numbers in IRF8-/- mice but fail to mature upon Toll-like receptor signaling and are functionally impaired in response to in vivo microbial stimulation. IRF8 deficiency does not affect the frequency or viability of DC precursors and as a result retroviral IRF8 transduction restores pDC development from DC progenitors in IRF8-/- mice.

Applications Reported: This V3GYWCH antibody has been reported for use in flow cytometric analysis.

Applications Tested: This V3GYWCH antibody has been tested by flow cytometric analysis of normal human peripheral blood cells. This may be used at less than or equal to 1 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

eFluor 450 is an alternative to Pacific Blue.  eFluor 450 emits at 446 nm and is excited with the violet laser line (405 nm). Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 405 nm; Emission: 445 nm; Laser: Violet Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$461.00
IRF8 Monoclonal Antibody (V3GYWCH), eFluor 450, eBioscience
$461.00

Product Information

Shipping & Returns

Description

PRODUCT DETAILS

Host: Mouse

Isotype: IgG1, kappa

Clonality: Monoclonal

Clone: V3GYWCH

Format: eFluor 450

Reactivity: Hu, Ms

Application: Flow Cytometry

Tested Dilution: 1.0 µg/test

Concentration: 0.2 mg/mL

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The V3GYWCH monoclonal antibody reacts with human and mouse interferon regulatory factor 8 (IRF8; ICSBP). IRF8 is a 50 kDa transcription factor that plays a critical role in the development of dendritic cells (DC). Specifically, IRF8 is essential in the development and differentiation of plasmacytoid DC (pDC) and CD8a+ DC. IRF8-/- mice are deficient in both pDC and CD8a+ DC populations. CD8a- DC are present in normal numbers in IRF8-/- mice but fail to mature upon Toll-like receptor signaling and are functionally impaired in response to in vivo microbial stimulation. IRF8 deficiency does not affect the frequency or viability of DC precursors and as a result retroviral IRF8 transduction restores pDC development from DC progenitors in IRF8-/- mice.

Applications Reported: This V3GYWCH antibody has been reported for use in flow cytometric analysis.

Applications Tested: This V3GYWCH antibody has been tested by flow cytometric analysis of normal human peripheral blood cells. This may be used at less than or equal to 1 µg per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test. It is recommended that the antibody be carefully titrated for optimal performance in the assay of interest.

eFluor 450 is an alternative to Pacific Blue.  eFluor 450 emits at 446 nm and is excited with the violet laser line (405 nm). Please make sure that your instrument is capable of detecting this fluorochrome.

Excitation: 405 nm; Emission: 445 nm; Laser: Violet Laser

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.