✨ New Arrivals Just Dropped!Explore
HomeStore

CD278 (ICOS) Monoclonal Antibody (ISA-3), PE, eBioscience

Product image 1

CD278 (ICOS) Monoclonal Antibody (ISA-3), PE, eBioscience

CD278 (ICOS) Monoclonal Antibody (ISA-3), PE, eBioscience

PRODUCT DETAILS

Host: Mouse

Isotype: IgG1, kappa

Clonality: Monoclonal

Clone: ISA-3

Format: PE

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.03 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The ISA-3 monoclonal antibody reacts with human ICOS (Inducible COStimulatory molecule), also known as H4, CRP-1 and AILIM. ICOS is a T cell specific activation molecule and a third member of the CD28/CTLA-4 family. Human ICOS has a relative molecular mass of 55-60 kDa, composed of 27 kDa and 29 kDa chains. Human ICOS on activated T cells has potent costimulatory activity for T cell activation and is required for humoral immune responses, in particular for memory B cell and plasma cell generation. ICOS binds to its ligand, B7h/B7RP-1 expressed on activated APCs (antigen presenting cells) and on a number of inflamed peripheral tissues. Plate-bound ISA-3 is costimulatory for T cells and induces production of IL-4, IL-5, IL-10 and other cytokines, but not IL-2. ISA-3 has the same reactivity pattern and characteristics as F44. ISA-3 was generated against the human ICOS antigen. C398.4A, anti-mouse ICOS/H4 (Product # 14-9949-82) , was shown to cross-react with human ICOS but binds to an epitope different from ISA-3. C398.4A stains activated cells brighter than ISA-3; however, it also exhibits higher staining of non-activated human peripheral blood or isolated PBMC. To achieve the brightest staining of ICOS on activated human T cells, please use Product # 13-9948-82 or Product # 12-9948-42 rather than Product # 11-9948-42 .

Applications Reported: The ISA-3 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This ISA-3 antibody has been pre-titrated and tested by flow cytometric analysis of unstimulated and CD3/CD28-stimulated (3 days) human blood cells. This can be used at 5 µL (0.03 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

Excitation: 488-561 nm; Emission: 578 nm; Laser: Blue Laser, Green Laser, Yellow-Green Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
$122.40

Original: $408.00

-70%
CD278 (ICOS) Monoclonal Antibody (ISA-3), PE, eBioscience

$408.00

$122.40

Product Information

Shipping & Returns

Description

PRODUCT DETAILS

Host: Mouse

Isotype: IgG1, kappa

Clonality: Monoclonal

Clone: ISA-3

Format: PE

Reactivity: Hu

Application: Flow Cytometry

Tested Dilution: 5 µL (0.03 µg)/test

Concentration: 5 μL/Test

Storage: 4°C, store in dark, DO NOT FREEZE!

Formulation: PBS with BSA and 0.09% sodium azide; pH 7.2

Purification: Affinity chromatography

Data Sheet: TDS


Specific Information

Description: The ISA-3 monoclonal antibody reacts with human ICOS (Inducible COStimulatory molecule), also known as H4, CRP-1 and AILIM. ICOS is a T cell specific activation molecule and a third member of the CD28/CTLA-4 family. Human ICOS has a relative molecular mass of 55-60 kDa, composed of 27 kDa and 29 kDa chains. Human ICOS on activated T cells has potent costimulatory activity for T cell activation and is required for humoral immune responses, in particular for memory B cell and plasma cell generation. ICOS binds to its ligand, B7h/B7RP-1 expressed on activated APCs (antigen presenting cells) and on a number of inflamed peripheral tissues. Plate-bound ISA-3 is costimulatory for T cells and induces production of IL-4, IL-5, IL-10 and other cytokines, but not IL-2. ISA-3 has the same reactivity pattern and characteristics as F44. ISA-3 was generated against the human ICOS antigen. C398.4A, anti-mouse ICOS/H4 (Product # 14-9949-82) , was shown to cross-react with human ICOS but binds to an epitope different from ISA-3. C398.4A stains activated cells brighter than ISA-3; however, it also exhibits higher staining of non-activated human peripheral blood or isolated PBMC. To achieve the brightest staining of ICOS on activated human T cells, please use Product # 13-9948-82 or Product # 12-9948-42 rather than Product # 11-9948-42 .

Applications Reported: The ISA-3 antibody has been reported for use in flow cytometric analysis.

Applications Tested: This ISA-3 antibody has been pre-titrated and tested by flow cytometric analysis of unstimulated and CD3/CD28-stimulated (3 days) human blood cells. This can be used at 5 µL (0.03 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.

Excitation: 488-561 nm; Emission: 578 nm; Laser: Blue Laser, Green Laser, Yellow-Green Laser.

Filtration: 0.2 µm post-manufacturing filtered.

 

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
CD278 (ICOS) Monoclonal Antibody (ISA-3), PE, eBioscience | Cytek Biosciences